3D Data Processing Software RANGE VIEWER
Changes from previous version
Exclusive software included as a standard accessory with the KONICA MINOLTA RANGE7/5 Non-Contact 3D Digitizer. Enables quick and simple operation from scanning to data merging.
Changes from Ver. 1.34 to Ver. 2.00
Additional functions:
- Run on Windows 7 Professional 64-bit
- Improve operability and GUI design for better recognition of the data
3D view under measurement mode will be 2 screens instead of 3 - "Edit marker holes" is added to the edit function. This makes it possible to fill the holes of marked portion.
- Possible to move the selected data even if it is not the data after immediate measurement through the initial position fitting by the instruction of corresponding points.
- Function to select group of points by editting becomes faster.
- Improve data quality at the edges by enforcing data noise deleting function.
Changes from Ver. 1.33 to Ver. 1.34
Bug fixes:
The following bugs have been fixed:
- Registration cannot be performed if scanning using the rotating stage is performed with the RANGE5/RANGE7 rotated 90°(so that the line between the lenses is vertical instead of horizontal).
- When markers are applied facing a very limited direction, and registration using markers is performed, data may be lost.
Additional functions:
- Operation when rotating measured data using a mouse has been improved to provide a more direct feeling.
Changes from Ver. 1.31 to Ver. 1.33
Bug fixes:
The following bugs have been fixed:
- When exporting STL files which reduced number of points (e.g. 1/4, 1/9), irregular polygons were created.
- When "selecting marker point" button is pressed, markers selected is smaller slightly.
Additional functions:
- To make easier to distinguish important markers from like a photogrammetry system, we add new color (light blue).
Changes from Ver. 1.20 to Ver. 1.31
Bug fixes:
The following bugs have been fixed:
- When using a laptop with a port replicator, the rotating stage could not be controlled in some cases.
- When an RS-USB adapter manufactured by Sigma A.P.O System Sales Co., Ltd. was used on an XP64 system, there were problems with controlling the rotating stage.
Additional functions:
- Addition of function to read marker coordinate values from external system such as layout machine or photogrammetry system.
- This enables high-accuracy measurement of subjects as large as around 2m.
- Data-reduction algorithm improves operating characteristics for large volumes of data.
- Improved noise-reduction algorithm provides improved surface quality.
Changes from Ver. 1.11 to Ver. 1.20
Bug fixes:
- The following bugs have been fixed:
- Slow STL data export speed
- Writing of improper data to file when saving reference markers
Additional functions:
- Function to change center of viewpoint rotation added.
- Angle settings of 10° , 15° , 24° , and 36° have been added for measurements using the rotation stage.
- Dark-surface measurement function has been added. (Konica Minolta Range7 must also have dark-surface measurement capability.)
Changes from Ver. 1.10 to Ver. 1.11
Bug fixes:
The following bugs have been fixed:
- A bug in which the application crashed under certain conditions when an element was deleted has been fixed.
Changes from Ver. 1.01 to Ver. 1.10
Bug fixes:
The following bugs have been fixed:
- When exporting multiple data including merged data to another company's application, data from the merged data onward could not be exported.
- When merging multi-focus data, data measured using multi-focus were handled as separate elements.
- When deleted data were included in the element list and export to another company's software was performed, the same data was exported twice.
- When multi-focus data are merged, no file could be output even when performing STL export.
Additional functions:
- Performance of mark detection and position matching for marker registration has been improved.
Specification changes:
- Windows XP x64 (64-bit version) has been added to the list of compatible OS.
- German and Chinese versions of the application and manuals are now available.
- French and Korean versions of the manuals only are now available.