LS-100/LS-110

Luminance Meters

A lightweight, compact, highly-portable luminance meter for measurements of a wide range of luminance conditions.

Specifications

Principal Specifications

Model Luminance Meter LS-100 Luminance Meter LS-110
Type SLR spot luminance meter for measuring light-source and surface brightness
Acceptance angle 1/3°
Optical system 85mm f/2.8 lens; SLR viewing system; flare factor less than 1.5%
Angle of view
Focusing distance 1014mm (40 in.) to infinity
Minimum measuring area Φ14.4mm Φ4.8mm
Receptor Silicon photocell
Relative Spectral Response* Within 8% (f1ยด) of the CIE spectral luminous efficiency V (λ)
Response time FAST: Sampling time: 0.1s, time to display: 0.8 to 1.0s; SLOW: Sampling time: 0.4s, time to display: 1.4 to 1.6s
Luminance units cd/m2 or fL (switchable)
Measuring range FAST: 0.001 to 299,900cd/m2 (0.001 to 87,530fL)
SLOW: 0.001 to 49,990cd/m2 (0.001 to 14,590fL)
FAST: 0.01 to 999,900cd/m2 (0.01 to 291,800fL)
SLOW: 0.01 to 499,900cd/m2 (0.01 to 145,900fL)
Accuracy 0.001 to 0.999cd/m2 (or fL): ±2% ±2 digits of displayed value
1.000cd/m2 (or fL) or greater: ±2% ±1 digit of displayed value
0.01 to 9.99cd/m2 (or fL): ±2% ±2 digits of displayed value
10.00cd/m2 (or fL) or greater: ±2% ±1 digit of displayed value
(Illuminant A measured at ambient temperature of 20 to 30°C/68 to 86°F)
Repeatability 0.001 to 0.999cd/m2 (or fL): ±0.2% ±2 digits of displayed value
1.000cd/m2 (or fL) or greater: ±0.2% ±1 digit of displayed value
0.01 to 9.99cd/m2 (or fL): ±0.2% ±2 digits of displayed value
10.00cd/m2 (or fL) or greater: ±0.2% ±1 digit of displayed value
(Measurement subject: Illuminant A)
Temperature/humidity drift Within ±3% ±1 digit (of value displayed at 20°C/68°F) within operatingtemperature /humidity range
Calibration mode Minolta standard/user-selected standard (switchable)
Color correction factor Set by numerical input; range: 0.001 to 9.999
Reference luminance 1; set by measurement or numerical input
Measurement modes Luminance; luminance ratio; peak luminance or luminance ratio
Display External: 4-digit LCD with additional indications
Viewfinder: 4-digit LCD with LED backlight
Data communication RS-232C; baud rate: 4800bps
External control Measurement process can be started by external device connected to data output terminal
Power source One 9V battery; power can also be supplied by optional Data Printer DP-10
Power consumption While measuring button is pressed and viewfinder display is lit: 16mA average
While power is on and viewfinder display is not lit: 6mA average
Operating temperature/humidity range 0 to 40°C, relative humidity 85% or less (at 35°C) with no condensation
Storage temperature /humidity range -20 to 55°C, relative humidity 85% or less (at 35°C) with no condensation
Dimensions 79×208×150mm (3-1/8×8-3/16×5-7/8 in.)
Weight 850g (30 oz.) without battery
Standard accessories Lens cap; Eyepiece cap; ND eyepiece filter; 9V battery; Case

Specifications are subject to change without notice.

*
Equivalent to 2% specified for T-1 series.
8% CIE(f1'),new JIS(1993)
2% old JIS